Shiraz E-Medical Journal

Published by: Kowsar

Visual Outcome, Refractive Error and Specular Microscopy Parameters Following Successful DSAEK

Meisam Ghanbari 1 , * , Mahmood Nejabat 1 , Mehrnoosh Maalhagh 1 and Seyed Mohammad Salar Zaheryani 1
Authors Information
1 Poostchi Ophthalmology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
Article information
  • Shiraz E-Medical Journal: 20 (1); e69214
  • Published Online: September 8, 2018
  • Article Type: Research Article
  • Received: April 8, 2018
  • Revised: August 2, 2018
  • Accepted: August 8, 2018
  • DOI: 10.5812/semj.69214

To Cite: Ghanbari M, Nejabat M, Maalhagh M, Zaheryani S M S. Visual Outcome, Refractive Error and Specular Microscopy Parameters Following Successful DSAEK, Shiraz E-Med J. Online ahead of Print ; 20(1):e69214. doi: 10.5812/semj.69214.

Abstract
Copyright © 2018, Author(s). This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited
1. Background
2. Methods
3. Results
4. Discussion
Acknowledgements
Footnote
References
  • 1. Mannis MJ, Mannis AA, Albert DM. Corneal transplantation: A history in profiles. 6. Japan: JP Wayenborgh; 1999.
  • 2. Sharma N, Maharana PK, Singhi S, Aron N, Patil M. Descemet stripping automated endothelial keratoplasty. Indian J Ophthalmol. 2017;65(3):198-209. doi: 10.4103/ijo.IJO_874_16. [PubMed: 28440248]. [PubMed Central: PMC5426124].
  • 3. Gorovoy MS. Descemet-stripping automated endothelial keratoplasty. Cornea. 2006;25(8):886-9. doi: 10.1097/01.ico.0000214224.90743.01. [PubMed: 17102661].
  • 4. Lee WB, Jacobs DS, Musch DC, Kaufman SC, Reinhart WJ, Shtein RM. Descemet's stripping endothelial keratoplasty: safety and outcomes: a report by the American Academy of Ophthalmology. Ophthalmology. 2009;116(9):1818-30. doi: 10.1016/j.ophtha.2009.06.021. [PubMed: 19643492].
  • 5. Ratanasit A, Gorovoy MS. Long-term results of Descemet stripping automated endothelial keratoplasty. Cornea. 2011;30(12):1414-8. doi: 10.1097/ICO.0b013e31820ca34b. [PubMed: 21993457].
  • 6. Price MO, Jordan CS, Moore G, Price FW Jr. Graft rejection episodes after Descemet stripping with endothelial keratoplasty: part two: the statistical analysis of probability and risk factors. Br J Ophthalmol. 2009;93(3):391-5. doi: 10.1136/bjo.2008.140038. [PubMed: 19019938].
  • 7. Kim K, Alder B, Vora GK, Carlson AN, Afshari NA, Kuo AN, et al. Textural interface opacity after Descemet-stripping automated endothelial keratoplasty. J Cataract Refract Surg. 2014;40(9):1514-20. doi: 10.1016/j.jcrs.2013.12.020. [PubMed: 25135544].
  • 8. Koenig SB, Covert DJ, Dupps WJ Jr, Meisler DM. Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK). Cornea. 2007;26(6):670-4. doi: 10.1097/ICO.0b013e3180544902. [PubMed: 17592314].
  • 9. Banitt MR, Chopra V. Descemet's stripping with automated endothelial keratoplasty and glaucoma. Curr Opin Ophthalmol. 2010;21(2):144-9. doi: 10.1097/ICU.0b013e3283360b95. [PubMed: 20040871].
  • 10. Allen MB, Lieu P, Mootha VV, Bowman RW, Petroll WM, Tong L, et al. Risk factors for intraocular pressure elevation after descemet stripping automated endothelial keratoplasty. Eye Contact Lens. 2010;36(4):223-7. doi: 10.1097/ICL.0b013e3181e6ae30. [PubMed: 20539235].
  • 11. Price MO, Price FW Jr. Endothelial cell loss after descemet stripping with endothelial keratoplasty influencing factors and 2-year trend. Ophthalmology. 2008;115(5):857-65. doi: 10.1016/j.ophtha.2007.06.033. [PubMed: 17868873].
  • 12. Terry MA, Shamie N, Chen ES, Hoar KL, Phillips PM, Friend DJ. Endothelial keratoplasty: the influence of preoperative donor endothelial cell densities on dislocation, primary graft failure, and 1-year cell counts. Cornea. 2008;27(10):1131-7. doi: 10.1097/ICO.0b013e3181814cbc. [PubMed: 19034127].
  • 13. Hjortdal J, Pedersen IB, Bak-Nielsen S, Ivarsen A. Graft rejection and graft failure after penetrating keratoplasty or posterior lamellar keratoplasty for fuchs endothelial dystrophy. Cornea. 2013;32(5):e60-3. doi: 10.1097/ICO.0b013e3182687ff3. [PubMed: 23086366].
  • 14. Anshu A, Price MO, Price FW Jr. Risk of corneal transplant rejection significantly reduced with Descemet's membrane endothelial keratoplasty. Ophthalmology. 2012;119(3):536-40. doi: 10.1016/j.ophtha.2011.09.019. [PubMed: 22218143].
  • 15. Khor WB, Han SB, Mehta JS, Tan DT. Descemet stripping automated endothelial keratoplasty with a donor insertion device: clinical results and complications in 100 eyes. Am J Ophthalmol. 2013;156(4):773-9. doi: 10.1016/j.ajo.2013.05.012. [PubMed: 23831219].
  • 16. Ang AY, Liu YC, Tan DT, Mehta JS. Descemet stripping automated endothelial keratoplasty with the EndoGlide Ultrathin graft insertion device. Expert Rev Med Devices. 2014;11(6):573-9. doi: 10.1586/17434440.2014.947273. [PubMed: 25101685].
  • 17. Busin M, Madi S, Santorum P, Scorcia V, Beltz J. Ultrathin descemet's stripping automated endothelial keratoplasty with the microkeratome double-pass technique: two-year outcomes. Ophthalmology. 2013;120(6):1186-94. doi: 10.1016/j.ophtha.2012.11.030. [PubMed: 23466268].
Creative Commons License Except where otherwise noted, this work is licensed under Creative Commons Attribution Non Commercial 4.0 International License .

Search Relations:

Author(s):

Article(s):

Create Citiation Alert
via Google Reader

Readers' Comments